Balluff / Industrial safety
BNI0098
BNI IOF-329-P02-Z038Balluff BNI0098 — Profisafe over IO-Link. Performance Level: e. Safety category (EN ISO 13849-1): 4. SIL (CEI 61508): 3. Maximum response time: 20 ms.
Technical essentials
- Number of safe outputs
- 2
- Digital outputs
- 2x PP / 2x PNP
- Interface
- PROFIsafe over IO-Link 1.1
- Connection slots
- 2x M12x1-Female connector, 8-pins, A-coded / 6x M12x1-Female connector, 5-pins, A-coded
Source consulted on 2026-10-19 Confirm family-level specifications for the selected variant.
| Performance Level | e |
| Safety category (EN ISO 13849-1) | 4 |
| SIL (CEI 61508) | 3 |
| Maximum response time | 20 ms |
| Approval / compliance | CE / Safety / cULus / WEEE |
| Number of safe inputs | 12 |
| Number of safe outputs | 2 |
| Total current US, sensor | 4.8 A |
| Total current UA, actuator | 8 A |
| Digital inputs | 14x PNP, type 3 |
| Digital outputs | 2x PP / 2x PNP |
| Interface | PROFIsafe over IO-Link 1.1 |
| Connection slots | 2x M12x1-Female connector, 8-pins, A-coded / 6x M12x1-Female connector, 5-pins, A-coded |
| Dimensions | 68 x 32,4 x 181,5 mm |
| Ambient temperature | -5...55 °C |
| IP rating | IP67 |
| Housing material | Zinc, Coulé sous pressure, nickel-plated |
Manufacturer catalogue selection. Supply, prices, availability and configuration must be confirmed with APM.
Technical documents
Language and revision: see the manufacturer document.
Technical documents Balluff ↗Manufacturer CAD models ↗
Explorer Balluff ↗