Balluff BTL4E6W — Magnetostrictive position measuring systems for hazardous areas. Design: Rod series Ex. Mounting: Flange Ø18h6 plus trous. Housing material: Stainless steel (1.4404). Maximum number of position magnets: 4.

Classic — pas de new conception (NNDI)

Technical essentials

Mounting
Flange Ø18h6 plus trous
Connection
Connection par serrage, 10 pins
Interface
CANopen DS301
Operating voltage Ub
20...28 VDC

Source consulted on 2026-10-20 Confirm family-level specifications for the selected variant.

Manufacturer specifications
DesignRod series Ex
MountingFlange Ø18h6 plus trous
Housing materialStainless steel (1.4404)
Maximum number of position magnets4
ConnectionConnection par serrage, 10 pins
InterfaceCANopen DS301
Measuring range3962 mm
Maximum linearity deviation±30 µm
Repeat accuracy± 2 LSB
Operating voltage Ub20...28 VDC
Ambient temperature-40...80 °C
IP ratingIP68
Approval / complianceCE / UKCA / CSA / IECEx / WEEE / CCC Ex / ATEX
Ex categoryATEX: 1G (EPL Ga) / ATEX: 1D (EPL Da) / IECEx: EPL Ga / IECEx: EPL Da / NEC 500: Class I, Division 1 / NEC 505: Class I, Zone 1